top of page
Force500 Logo Blue.png

Force 500: Total Flooding Fire Protection System

  • Medical Equipment/Facilities

  • Merchant Marine Vessels

  • Mix Rooms

  • Network Centers

  • Turbine Enclosures

  • Electric Utility Facilities

  • Engine Protection

  • IT Systems/Software

  • Gas Compressor Rooms

  • Manufacturing Facilities

  • Off-Shore Oil Rigs

  • Paint Rooms

  • Pleasure Craft

  • Pump Stations

  • Mass Transit Vehicles

  • Clean Rooms

  • Combat Vehicles

  • Computer Rooms

  • Data Storage Facilities

  • Libraries & Museums

  • Archives

  • Automobiles

  • Cable Spreading Rooms

  • Cellular Sites

  • Generators

Cylinder 500 A.png

What is it?

The SEVO™ 1230 FORCE500™ Clean Agent Fire Suppression System is a revolutionary new technology for clean agent systems that utilizes FK-5-1-12 Fire Protection Fluid and its unique ability to be pressurized to 500 psi (34.5 bar). It allows for longer pipe runs and smaller pipe diameters in addition to its cost saving benefits of using less clean agent in smaller and/or fewer cylinders per project. Along with these new engineering capabilities, it includes standard monitoring components such as an integrated pressure switch, pressure gauge, and gauge guard. The low vapor pressure of FK-5-1-12 Fluid allows for the use of low pressure welded cylinders and Schedule 40 piping. With these revolutionary features, the FORCE500 is a standout to conventional 360 psi (25 bar) systems.

Group 2.png

500 PSI Efficiency

  • Less Clean Agent Needed

  • Smaller and/or Fewer Cylinders Needed

  • Increased Single Nozzle Coverage

  • Retrofit of Existing Halon & HFC Systems

  • Efficient and Flexible Pipe Networks

Retrofit Capability

SEVO Systems’ retrofit of existing halon systems is a 1 for 1 cylinder and nozzle replacement that includes a minimal cylinder footprint expansion. Retrofitting of existing halon systems features longer pipe runs, reduced nozzle pressure, resulting in a reduction of overall cost.

Note: All halon retrofit systems must be installed in accordance with approvals and listings including NFPA/ISO and local standards.

Installed.png

Smaller/Fewer
Cylinders

The higher flow rate of the FORCE500 system allows for enhanced piping limitations. When protecting a main and subfloor hazard with a 360 psi system, a minimum additional 5% agent is required in the subfloor to compensate due to these piping limitations. By Utilizing the FORCE500 system, no additional agent is required for the subfloor or subsequent areas

360 vs 500.png

Improved Pipe
Networks

The FORCE500 features longer pipe lengths between the cylinder and nozzle as well as longer distances between the first and last nozzle. This allows for complex nozzle layouts with smaller pipe sizes and longer pipe runs.

ul-listed.png
ulc-logo.png
ce-logo.png
SEVO Timeline Ф.png

Less agent.

Agent Used-01-01.png

The higher flow rate of the FORCE500 system allows for enhanced piping limitations. When protecting a main and subfloor hazard with a 360 psi system, a minimum additional 5% agent is required in the subfloor to compensate due to these piping limitations. By Utilizing the FORCE500 system, no additional agent is required for the subfloor or subsequent areas

bottom of page